Model No.ASHP()

BrandAmrta or OEM

TypeCooling / Heating

Indoor Machine Noise<23dB

CertificationCE

China Energy Efficiency StandardLevel 1

Cooling/HeatingCooling/Heating

Power SourceElectrical

Power TypeDC

ConditionNew

Compressor BrandCopeland / Danfoss / Daikin / Panasonic

RefrigerantR410A / R407c / R134A / R22

Power Supply380-415V, 440-460V, 50HZ/60HZ

Casing(Optional)Stainless Steel 304/316

Compressor Qty/Circult1/2

Electric PartsSchneider Brand

Running ConditionLow Ambient Temperature -25degree C

EvaporatorPlate / Tube And Tube Type

Application FieldsLow Ambient Temperature To Need Heating

Additional Info

PackagingPlywood Casing or Standard Package Suitable for Sea and Air Transport

Productivity5000SETS/Year

TransportationOcean,Air

Place of OriginChina

Supply Ability400PCS / Month

HS Code8418612090

PortQingdao,Shandong,China

Payment TypeL/C,T/T

IncotermFOB,CFR,CIF

Product Description

Amrta Low Ambient Temperature Air Source Heat Pump unit is highly efficient on heating and cooling applications. They use of green refrigerant R410A are more eco-friendly and perform perfectly even under low ambient temperature of -25 oC. Moreover, the Air Source Heat Pump units are space saving, quiet running, and simple to install which only requires water pipe and electric wire for connections. This monobloc series is cost effective and suitable for heating and cooling for apartment and villas.


-25 Low Temperature Air Source Heat Pump Unit


Why this choice?
Amrta's AC range of chillers with the EVI-cycle increase the maximum temperature difference remarkably and provide a COP up to 4.5, which makes the hot water system much more efficient. 
They can be widely used in the commercial situation.


Characteristics

01.High efficient. The application of EVI technology together with the high efficiency heat exchanger improves the heat exchanging rate.
02.Low working temperature. Units achieve optimum performance at ambient temperature as low as -25oC, ensuring 60oC hot water all year round.
03.Easy control Intelligent control system with the Carel controller makes it much easier to control your unit whenever you need.
04.EVI technology. The EVI compressor ensures the unit operate safely at low ambient temperature with higher efficiency and less noise.

05.Structure. Panels and base frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
06.Compressor. Hermetic scroll type compressor, equipped with the crankcase heater and thermal protection with thermal overload cut-out and crankcase heater mounted on rubber vibration isolators
07.Axial fan. External rotor type axial fans, equipped with single phase direct drive motors, low noise 6 poles, protection level IP54, plastic blade for low noise.
08.Evaporator. High efficiency tank type heat exchanger, factory insulated with flexible close cell material. 
09.Condenser. Coils are consisting of seamless copper tubes mechanically expanded into blue hydrophilic aluminum fins, protected with flexible plastic grill. 
10.Refrigerant circuit. Copper tube connection with charge valve, filter, sight glass, gas-liquid separator, electronic expansion valve, low pressure switch with automatic reset, high pressure switch with manual reset. The heat pump unit is completed also with 4-way valve, liquid receiver and one way valve.
11.Water circuit. Without water pump and expansion tank, but with paddle flow switch.
12.Electric panel
consists of:  
Compressor contactor;
Compressor protection breaker;
Fan motor protection breaker;
Control circuit protection breaker;
Programmable microprocessor controller
Low Ambient Temperature Air Source Heat Pump Aplication

Technical Data

 Item                                                                                               Model ASHP-10L ASHP-15L ASHP-20L
DB/WB IN/OUT water Capacity Unit
7ºC/6ºC 36ºC/41ºC Heating kW 9.6 14.5 19.1
Power input kW 2.5 3.8 5.1
50ºC/60ºC Heating kW 9.8 14.5 19.8
Power input kW 3.3 4.8 6.5
-12ºC/-14ºC 36ºC/41ºC Heating kW 6.1 9.2 11.8
Power input kW 2.32 3.70 4.70
50ºC/60ºC Heating kW 6.6 9.8 12.8
Power input kW 3.2 4.8 6.4
-20ºC/-ºC 36ºC/41ºC Heating kW 5.2 7.7 10.3
Power input kW 2.30 3.60 4.60
50ºC/55ºC Heating kW 5.4 8.1 10.8
Power input kW 2.9 4.3 5.8
-25ºC/-ºC 36ºC/41ºC Heating kW 4.5 6.0 8.9
Power input kW 2.40 3.40 4.80
50ºC/55ºC Heating kW 4.7 6.8 9.5
Power input kW 2.9 4.5 5.9
35ºC/--- 12ºC/7ºC Cooling kW 7.2 10.2 14.2
Power input kW 2.7 3.7 5.2
Compressor Type   Scroll Scroll Scroll
Brand   Copeland Copeland Copeland
Qty   1 1 1
Control methods   Electronic expansion valve
Condensing fan Type   Axial, plastic fan blade Axial, plastic fan blade Axial, plastic fan blade
Qty   1 2 2
Power input w 90 90 90
Max power input kW 4.1 5.8 8.2
Max working current A 18 29 36
Pipe size R1'' R1'' R1''
Evaporator type   High efficiency tank type heat exchanger
Water flow Cooling (△5k) m3/h 1.24 1.75 2.4
Heating (△5k/△10k) m3/h 1.58/0.79 2.49/1.25 2.9/1.45
Water resistance kPa 40 45 46
Refrigerant Type   R410A
Charge amount kg 3.6 5.3 6.1
Working range ºC -25ºC-46ºC
Power supply 1N~220V 50Hz
Dimension mm 1200x560x858 1000x560x1316 1100x620x1316
Noise level dB(A) 54 56 56
Weight kg 122 150 170
Note: Without water pump and expansion tank, but with paddle flow switch.

Why Choose Amrta?

Amrta Central Air Conditioning

Product Catalog

Amrta Air Conditioner Product Catalog


Project

Amrta Air Conditioner Project


Ordering Process

Air Source Heat Pump Unit Ordering Process


Product Categories : Heat Pump System > Low Ambient Temperature Air Source Heat Pump

Product Images
  • Cold Climate Air Source Heat Pump Air Conditioner
  • Cold Climate Air Source Heat Pump Air Conditioner
  • Cold Climate Air Source Heat Pump Air Conditioner
  • Cold Climate Air Source Heat Pump Air Conditioner
Email to this supplier
  • *Subject:
  • *Messages:
    Your message must be between 20-8000 characters