Horizontal Type Air Handling Unit

Our firm insists all along the quality policy of "product top quality is base of company survival; purchaser pleasure could be the staring point and ending of an organization; persistent improvement is eternal pursuit of staff" plus the consistent purpose of "reputation very first, buyer first" for Horizontal Type Air Handling Unit,Horizontal Type Fresh Air Handling Unit,Horizontal Vertical Type Air Handling Unit,Horizontal Type Air Handling Unit Equipments We hope to establish additional organization interactions with prospects all over the entire world.
View : List Grid
Compact Medical Horizontal Air Handling Unit

Model No. : AHU, AVU, AMU

An Air Handling Unit (most of the times abbreviated to AHU), or Air Handler, is a central air conditioner station that handles the air that, usually, will be supplied into the buildings by the ventilation ductwork (connected to the AHU). Handling...

 Click for details
China Horizontal Type Air Handling Unit Suppliers
Horizontal Type Air Handling Unit

Air flow 1,000m3/h-50,000m3/h,Coil type 4rows/6rows/8rows

AMRTA air handling unit mainly constructed with filter, heat exchanger, fan motor, fan blower and other main components.

Operation & Maintenance:
1.Before the unit operation, check the water pipe valves system and duct equipment. Make sure everything is under good condition.
2.Check the fan motor and blower moving parts regularly for their connection, operation and rotating direction. Readjust it if necessary.
3.Air filter cleaning should be carried out every month before and during operation.
4.During winter, coil water should be drained out if not operating. If the unit needs to operate during winter time, make sure when the unit stops running, the coil water must circle the system and the fresh air damper must be closed to prevent coil freezing. If the unit stops operation for a long duration, coil water must be drained out.
5.Clean soft water must be used for chilled water and hot water system. Every year, wafer chemical treatment must be performed to eliminate the contamination in the system and apply compressed air or wafer for cleansing the fin coil surface, drain pan and U-trap bend.
6.Regular checking must be performed for the motor bearing lubrication condition and belt tightness.

Horizontal type air handling unit