Jinan Amrta Air Conditioning Co.,Ltd

High COP Air Source Heat Pumps,Portable Air Source Heat Pump,Office Building Air Source Heat Pump

Home > Products > Heat Pump System > Low Ambient Temperature Air Source Heat Pump > -25 Degrees DC Inverter Air Source Heat Pumps

-25 Degrees DC Inverter Air Source Heat Pumps

Basic Info

Model No.ASHP()

BrandAmrta or OEM

TypeCooling / Heating

Noise LevelUltra Low

MountingFloor Standing

Lifetime15~20 years

CertificationCE

ConditionNew

Compressor BrandCopeland / Danfoss / Daikin / Panasonic

RefrigerantR410A / R407c / R134A / R22

EvaporatorPlate / Shell And Tube

Application FieldsHospital, Hotel, School, Swimming Pool

Power Supply380-415V, 440-460V, 50HZ/60HZ

Compressor Qty/Circult2/3/4

Casing(Optional)Stainless Steel 304/316

Running ConditionLow Ambient Temperature -25degree C

Additional Info

PackagingPlywood Package Unit

Productivity5000SETS/Year

TransportationOcean,Air

Place of OriginChina

Supply Ability400PCS / Month

HS Code8418612090

PortQingdao,Shandong,China

Payment TypeL/C,T/T

IncotermFOB,CFR,CIF

Product Description

The nominal refrigeration COP (efficiency) of Air Source Heat Pump is very high averaging over 4.2 but importantly the performance of these units in reducing ambient temperatures is also at an extremely high level. Designed to operate in ambient temperatures as low as -25ºC the range is more than capable of operating with high efficiency in winter temperatures. These units incorporate a built in heating system circulation pump, control for hot water production including Y Plan valve operation along with full weather compensation and sophisticated controls which give a very short defrost cycle of approximately 6 minutes in lower ambient temperatures.


Why this choice?
Amrta Air Conditioner of chillers with the EVI-cycle increase the maximum temperature difference remarkably and provide a COP up to 4.5, which makes the hot water system much more efficient. 
They can be widely used in the commercial situation.


Characteristics

High efficient
The application of EVI technology together with the high efficiency heat exchanger improves the heat exchanging rate.
Low working temperature
Units achieve optimum performance at ambient temperature as low as -25oC, ensuring 60oC hot water all year round.
Easy control
Intelligent control system with the Carel controller makes it much easier to control your unit whenever you need.
EVI technology
The EVI compressor ensures the unit operate safely at low ambient temperature with higher efficiency and less noise.

Structure
Panels and base frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
Compressor
Hermetic scroll type compressor, equipped with the crankcase heater and thermal protection with thermal overload cut-out and crankcase heater mounted on rubber vibration isolators
Axial fan
External rotor type axial fans, equipped with single phase direct drive motors, low noise 6 poles, protection level IP54, plastic blade for low noise.
Evaporator
High efficiency tank type heat exchanger, factory insulated with flexible close cell material. 
Condenser
Coils are consisting of seamless copper tubes mechanically expanded into blue hydrophilic aluminum fins, protected with flexible plastic grill. 
Refrigerant circuit
Copper tube connection with charge valve, filter, sight glass, gas-liquid separator, electronic expansion valve, low pressure switch with automatic reset, high pressure switch with manual reset.
The heat pump unit is completed also with 4-way valve, liquid receiver and one way valve.
Water circuit
Without water pump and expansion tank, but with paddle flow switch.
Electric panel
consists of:  
Compressor contactor;
Compressor protection breaker;
Fan motor protection breaker;
Control circuit protection breaker;
Programmable microprocessor controller
Low Ambient Temperature Inverter Air Source Heat Pump Application

Technical Data

 Item                                                                                               Model ASHP-10L ASHP-15L ASHP-20L
DB/WB IN/OUT water Capacity Unit
7ºC/6ºC 36ºC/41ºC Heating kW 9.6 14.5 19.1
Power input kW 2.5 3.8 5.1
50ºC/60ºC Heating kW 9.8 14.5 19.8
Power input kW 3.3 4.8 6.5
-12ºC/-14ºC 36ºC/41ºC Heating kW 6.1 9.2 11.8
Power input kW 2.32 3.70 4.70
50ºC/60ºC Heating kW 6.6 9.8 12.8
Power input kW 3.2 4.8 6.4
-20ºC/-ºC 36ºC/41ºC Heating kW 5.2 7.7 10.3
Power input kW 2.30 3.60 4.60
50ºC/55ºC Heating kW 5.4 8.1 10.8
Power input kW 2.9 4.3 5.8
-25ºC/-ºC 36ºC/41ºC Heating kW 4.5 6.0 8.9
Power input kW 2.40 3.40 4.80
50ºC/55ºC Heating kW 4.7 6.8 9.5
Power input kW 2.9 4.5 5.9
35ºC/--- 12ºC/7ºC Cooling kW 7.2 10.2 14.2
Power input kW 2.7 3.7 5.2
Compressor Type   Scroll Scroll Scroll
Brand   Copeland Copeland Copeland
Qty   1 1 1
Control methods   Electronic expansion valve
Condensing fan Type   Axial, plastic fan blade Axial, plastic fan blade Axial, plastic fan blade
Qty   1 2 2
Power input w 90 90 90
Max power input kW 4.1 5.8 8.2
Max working current A 18 29 36
Pipe size R1'' R1'' R1''
Evaporator type   High efficiency tank type heat exchanger
Water flow Cooling (△5k) m3/h 1.24 1.75 2.4
Heating (△5k/△10k) m3/h 1.58/0.79 2.49/1.25 2.9/1.45
Water resistance kPa 40 45 46
Refrigerant Type   R410A
Charge amount kg 3.6 5.3 6.1
Working range ºC -25ºC-46ºC
Power supply 1N~220V 50Hz
Dimension mm 1200x560x858 1000x560x1316 1100x620x1316
Noise level dB(A) 54 56 56
Weight kg 122 150 170
Note: Without water pump and expansion tank, but with paddle flow switch.

Winter Monoblock Air to Water Heat Pump Inverter


Product Categories : Heat Pump System > Low Ambient Temperature Air Source Heat Pump

Product Images
  • -25 Degrees DC Inverter Air Source Heat Pumps
  • -25 Degrees DC Inverter Air Source Heat Pumps
  • -25 Degrees DC Inverter Air Source Heat Pumps
  • -25 Degrees DC Inverter Air Source Heat Pumps
  • -25 Degrees DC Inverter Air Source Heat Pumps
Email to this supplier
  • *Subject:
  • *Messages:
    Your message must be between 20-8000 characters