Model No.: AW60~AW260
Brand: Amrta or OEM
Type: Cooling Only With Electric Heater/Cooling Only/Heat Pump
Air Tube Material: Galvanized Sheet
Corrosion Durability: General
Operating Voltage: 380/400 VAC
Noise Level: Ordinary
Mounting: Floor Standing
Lifetime: 15~20 years
Certification: CE
Condition: New
Compressor Brand: Copeland / Danfoss / Daikin / Panasonic
Refrigerant: R410A / R407c / R134A / R22
Evaporator: Plate / Shell And Tube
Application Fields: Cooling Machine
Power Supply: 380-415V, 440-460V, 50HZ/60HZ
Compressor Qty/Circult: 2/3/4
Casing(Optional): Stainless Steel 304/316
Running Condition: Low Ambient Temperature -20degree C
Controller: PUNP Or SIEMENS PLC
Packaging: Plywood Casing or standard package suitable for sea and air transport
Productivity: 5000SETS/Year
Transportation: Ocean,Air
Place of Origin: China
Supply Ability: 400PCS / Month
HS Code: 8418612090
Port: Qingdao,Shandong,China
Payment Type: L/C,T/T
Incoterm: FOB,CFR,CIF
The Air Source Heat Pump Cooling and Heating with cooling capacity from 20kW to 260kW. Supply cooling water in summer to cooling.and heating water in winter to heating, The series Modular Air Source Heat Pump Unit will equipped with water pump and terminals, such as Water Chilled Fan Coil Unit or Water Chilled Air Handling Unit. With hydrophilic modular is an optional, such as water pump(one use, one standby), valves, flow switch, water tank etc. These spare parts maybe in one casing box, which is complete packaged and transport convenient.
Application areas
● Offices, Hotels, Hospitals, Industry
● Administration
● Light commercial and residential buildings
Why this choice?
● Very high efficiency with R410A
● Very low noise operation
● R410A scroll compressors
● Advanced control
● Unit with pump and optional buffer tank
● Very compact for outdoor or indoor installation
Characteristics
The master module can work independently or together with up to 16 slave modules.
Units with V type heat exchanger: panels, frame and base are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
3-phase scroll type compressor, with builtin thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.
External rotor type axial fans, equipped with three phase direct drive motors, low noise 8 poles, protection level IP54, provided with a protective outlet grille.
Evaporator built with high efficiency shell and tube type heat exchanger, factory insulated with flexible close cell material.
Condenser built with seamless copper tubes mechanically expanded into blue hydrophilic aluminum fins.
Refrigerant circuit complete with charge valves, filter drier, sight glass, gas-liquid separator, thermostatic expansion valve, high & low pressure switch. The heat pump unit is completed also with 4-way valve, liquid receiver and one way valve.
Hydraulic circuit built with galvanized pipe, complete with water discharge connection for tube in tube heat exchanger and flange type hydraulic connectors in two directions easy for connections from both sides of the units.
Electric panel consist of:
Compressor contactor, fan motor contactor, compressor protection breaker, fan protection breaker, phase sequence relay and microprocessor with function display (display only for master/packaged unit)
Automatic operation dramatically reducing maintenance cost thanks to reliable microprocessor system.
Optional
Paddle flow switch;
Metallic filter for hydraulic circuit;
Water pump;
Rubber antivibration mounting;
Heat recovery functions.
Technical Data
Model AW | 60 | 100 | 130 | 200 | 260 | ||
Cooling capacity* | kW | 65 | 97.5 | 130 | 195 | 260 | |
Cooling power input | kW | 20.8 | 31.4 | 42.1 | 63.6 | 84.2 | |
Heating capacity** | kW | 68 | 102 | 136 | 204 | 272 | |
Heating power input | kW | 20.2 | 30.6 | 41 | 61.2 | 82 | |
Max Input Power | kW | 24 | 35.7 | 47.7 | 71.4 | 95.4 | |
Max Input current | A | 50 | 74 | 97 | 148 | 194 | |
Cooling Running Current | A | 46 | 68 | 89 | 136 | 178 | |
Start-Up Current | A | 167 | 187 | 206 | 374 | 412 | |
Compressor | |||||||
Power supply | / | 380/3/50 | |||||
Brand/Type | / | Daikin/Scroll | |||||
Refrigerant | / | R410a | |||||
Qty/refrigerant circuit | Nr. | 2 | 3 | 4 | 6 | 8 | |
Cooling power input* | kW | 2*9.4 | 3*9.63 | 4*9.77 | 6*9.63 | 8*9.77 | |
Heating power input** | kW | 2*9.1 | 3*9.36 | 4*9.5 | 6*9.36 | 8*9.5 | |
Energy adjustment | % | 0-25-50-75-100 | |||||
Axial fan | |||||||
Quantity | Nr. | 2 | 2 | 2 | 4 | 4 | |
Power input | kW | 2 | 2.5 | 3 | 5 | 6 | |
Airflow | m3/h | 24000 | 36000 | 48000 | 72000 | 96000 | |
Evaporator | |||||||
Type | / | Shell and tube heat exchanger | |||||
Water flow when cooling | m3/h | 11.2 | 16.8 | 22.4 | 33.6 | 44.8 | |
Water flow when heating | m3/h | 11.7 | 17.6 | 23.4 | 35.1 | 46.8 | |
Water side pressure drop *** | kPa | 46 | 52 | 55 | 52 | 55 | |
Water connection size | DN | 50 | 50 | 65 | 2x50 | 2x65 | |
Noise level*** | dB(A) | 70 | 72 | 72 | 74 | 75 | |
Dimensions | |||||||
V type coil | Length | mm | 2000 | 2207 | 2207 | 2207 | 2207 |
Width | mm | 1060 | 1300 | 1300 | 2207 | 2207 | |
Height | mm | 1957 | 2076 | 2076 | 2096 | 2096 | |
Net weight | kg | 620 | 1060 | 1120 | 2160 | 2280 | |
Working weight | kg | 635 | 1090 | 1155 | 2220 | 2350 |