Jinan Amrta Air Conditioning Co.,Ltd

Semi-custom Air Conditioner with Electric Heater,Low Ambient Temperature Packaged Unit,Rooftop Packaged Unit for Gymnasium

Rooftop Air Handling Unit

Basic Info

Model No.RTU()

BrandAmrta or OEM

TypeEvaporative Air Cooler

Air Tube MaterialGalvanized Sheet

Corrosion DurabilityGeneral

Operating Voltage380/400 VAC

Noise LevelLow

MountingFloor Standing

Lifetime15~20 years

CertificationCE

ConditionNew

Application FieldsMechanical Engineering, School, Airport, Shopping Mall, Industrial Buildings

RefrigerantR410A/R407c/R134A/R22

CompressorDanfoss/Copeland/Panasonic/Daikin

Cooling Capacity12kw-300kw

Additional Info

PackagingPlywood Package or Plastic Film Wrapped

Productivity600PCS/Year

TransportationOcean

Place of OriginChina

HS Code8418612090

PortQingdao,Shandong,China

Payment TypeL/C,T/T,Western Union

IncotermFOB,CFR,CIF

Product Description

Amrta HVAC Rooftop Packaged Unit With Hot Water Coil is convertible single package high efficiency rooftops. All models have independent refrigeration circuits for efficient part load operation. Although the units are primarily designed for curb mounting on a roof, they can also be slab-mounted at ground level or set on steel beams above a finished roof. Every Air Conditioner unit is completely charged, wired, piped, and tested at the factory to provide a quick and easy field installation. All models ( including those with an economizer ) are convertible between bottom and horizontal duct connections. Electric heater are available as factory - installed options only. 


Application areas
● Large and light commercial buildings (Retail, Airports, Restaurants, shops, petrol stations)
● Cinemas, Theaters

● Industrial buildings and logistic centers


Why this choice?
● Energy efficient solution
● Cost effective package for fast and easy installation
● Multiple heating options available
● Fresh air control and free cooling management

● Wide choice of communication interfaces


Characteristics
Structure
Panels and frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
Direct expansion coils with condensate drain tray.
Hermetic compressor
High efficiency scroll compressor for the whole range, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.
Ripple type acoustic insulation for compressor section, and thermal insulation for coil and fan section, low noise.
Centrifugal fan
Forward curve centrifugal fans for air treatment section and axial fans for condensation section.
Front, side and underside air discharge of the treatment unit.
High external pressure, long air supply distance.
Electric panel
Electric panel consists of breakers and contactors for compressors and fan motors, phase sequence relay and other necessary protection devices for the main components.
Easy operation line controller
Cooling / Heating / Auto
Error indication
Timing on/off
Optional
Economizer with fresh, return air dampers and fresh air hood
Free cooling function for low ambient temperature
Low ambient control device for operation of outdoor units at ambient temperatures from less than 20°C down to -10°C
BMS devices
T3 (Tropical climate)
Roof curb
Metal/aluminum filter
Heat recovery to 100%
Evaporating section: double skin with 50mm polyurethane foam
Optional water heating coil
Metal or plastic mesh on condenser coil
Optional supply / return air configurations
Upgraded plug fan
G4 filter, plate and bag filter
Portable Rooftop Packaged Unit For Tent

Heating Possibilities
Electric heater

The electric heater comprises of shielded resistance heaters, which are smooth stainless steel tubes 6 W/cm2 capacity. High temperature limit control offers overload protection and is set to 90°C and located at less than 150mm after electric heaters. This is provided as a standard feature on the electric heater, with the electric power supply cables made of reticulated silicon rubber, resistant to temperatures up to 200°C. For any rooftop unit size, three sizes of electric heater are 
available, S (standard), M (Medium) and H (high).
Hot water coil
Hot water coils offer fully modulating control through the use of a 3 way valve. The hot water coil, connections and valves are all tested at pressure of 15 bars. 
Frost protection is provided by forcing the opening the 3 way valve when supply temperature from hot water coil falls below 8°C and by stopping the outdoor fan when that supply temperature falls below 6°C. In addition to that, the 3 way valve is also opened at 10% value if the outdoor temperature falls below an adjustable value.
Hot water coils are always factory fitted, wired and fully tested, prior to shipment.
Air Source Heat Pump Unit


Rooftop Packaged Unit Technical Data

Model 

RTU45

RTU50

RTU60

RTU75

RTU90

RTU105

Cooling capacity

kW

44.5

50

60

70

90

105

Heating capacity

kW

48.7

54.3

64

75.4

96.2

113.2

Power supply

  380V / 3Ph / 50HZA

Cooling power input

kW

17

19.5

22.8

26.7

32.9

39.7

Heating power input

kW

15.6

18

21

24.8

30.4

36.7

Start current

A

168

186

175

199

197

266

Working current in cooling

A

31.7

35.6

39.9

48.3

61

70.6

Working current in heating

A

29.9

33.5

37.5

45.4

57.3

66.3

Throttle methods

Thermal expansion valve

Circuits

2

2

2

2

3

3

Refrigerant

R410A

Compressor

Type

Scroll type        380V / 3Ph / 50HZA

Qty

2

2

2

2

3

3

Condenser side

Condenser

Type

Al+copper tube

Axial fan

Qty

1

1

1

1

2

2

Drive

Direct drive

Motor power

kW

0.25

0.37

0.37

0.55

0.75

0.75

Air flow

m/h

4600

7800

7800

9000

12600

12600

Evaporator side

Evaporator

Type

Al+copper tube

Centrifugal fan

Qty

1

1

1

1

1

1

Motor power

kW

3

3

4

4

5.5

5.5

Air flow

m/h

7600

8500

10900

12500

16000

19500

Drive

Direct drive

Belt drive

External static pressure(Pa)

250

250

300

300

300

300

Filter

Aluminum frame filter G3

Noise level dB(A)

73

73

73

75

74

75

Dimension

L

mm

2268

2268

2298

2298

2878

2878

W

mm

1440

1440

1650

1650

2140

2270

H

mm

1167

1167

1400

1400

1964

1964

Weight

kg

750

770

830

860

1160

1350

* Performance values refer to the following conditions:
Cooling: room air temperature 27.0°C DB RH 50%, ambient air temperature 35°C;
Heating: room air temperature 20.0°C DB, ambient air temperature 7°C DB / 6°C WB.
** Noise level measured by adopting average value in the noise lab with background noise of 25 dB(A), at a distance of 1.5m high fan speed.

Ducted Split Unit



Product Categories : Rooftop Packaged Unit > Rooftop Packaged Unit With Hot Water Coil

Product Images
  • Rooftop Air Handling Unit
  • Rooftop Air Handling Unit
  • Rooftop Air Handling Unit
  • Rooftop Air Handling Unit
  • Rooftop Air Handling Unit
Email to this supplier
  • *Subject:
  • *Messages:
    Your message must be between 20-8000 characters