Model No.: AA()
Brand: Amrta or OEM
Type: Cabinet Air Conditioner
Air Tube Material: Galvanized Sheet
Corrosion Durability: Ultrahigh
Noise Level: Ultra Low
Mounting: Split
Lifetime: 10~15 years
Certification: CE
Condition: New
Electric Parts: Schneider Brand
Operating Voltage: 380-415, 440, 460, 50/60Hz
Application Fields: Supermarket, Hospital, Pharmaceutical And Building
Capacity: 20kw-104kw
Power Source: Electrical
Power Type: AC
Refrigerant: R22/R407c/R410A/R134A
Compressor: Copelan/Danofss/Pansonic/Daikin Brand
Filter Type: Pre, Medium And HEPA(Optional)
Cooling/Heating: Cooling/Heating
Packaging: Standard Package
Productivity: 10000PCS/Year
Transportation: Ocean,Air
Place of Origin: China
Supply Ability: 1000PCS/Month
HS Code: 8418612090
Port: Qingdao,Shandong,China
Payment Type: L/C,T/T,Western Union
Incoterm: FOB,CFR,CIF
A Ducted Split System is a great choice for people who want to heating or cooling by managing airflow using a `zoned` system. A Ducted Split Unit is an Air Conditioning system that uses ductwork inside the roof or under the floor to distribute air throughout the indoor. It comprises of an Indoor Unit and an Outdoor Compressor, much like a Split System. The Ducted Split indoor unit is placed on the inside of the house, either under your floor or inside your ceiling, and is connected to the outdoor unit. The indoor unit distributes the air through the area it is installed in via strategically placed outlets throughout your home. A Ducted Split Air Conditioner is able to heat or cool certain areas of your home using a zoning method, or the entire house at one single time for smaller homes (19sq – 25sq approx).
Application areas
Wide application as hotel, apartment, villa, factory, shopping center, office building, school, etc.
Why this choice?
High efficiency: Adopts famous brand compressor, multi-level adjustment, high efficiency anti-corrosion hydrophilic aluminum foil, which make the efficiency up to 30%.
Extraordinary performance: Adopts well-know brand opponents, such as EMERSON, SPORLAN, DANFOSS brand etc.
Intelligent control: Micro computer control, cooling, heating, auto, ventilation can be free switching.
Characteristics
11 sizes available ranging from 19.5 kW to 103.7 kW cooling capacity.
Cooling only and heat pump version.
Wide application as hotel, apartment, villa, factory, shopping center, office building, school, etc.
Panels and frame are made from metal steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
High efficiency scroll compressor for the whole range, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.
Compact indoor design, long air supply distance.
Outdoor units are equipped with low noise axial fans.
Indoor units are equipped with quiet centrifugal fans.
Split installation, connected by means of flare/welding coupling.
Easy operation line controller:
• Cooling/Heating/Fan/Auto
• Error indication
• Timing On/Off
• Multi safety protection
• High/low pressure protection
• Overheat protection
• Current overload protection
• Phase sequence relay
• Time delay and antifreeze switch
Optional
• Additional electric heater on indoor unit
• Additional heating coil on indoor unit
Technical Data
Model | Unit | AA20 | AA25 | AA32 | AA36 | AA42 | AA48 | |
Nominal cooling capacity* | kW | 19.5 | 24.8 | 31.2 | 35.6 | 41.3 | 47.4 | |
Nominal heating capacity** | kW | 22.6 | 28.9 | 35.8 | 40.8 | 46.9 | 54.4 | |
Connection |
|
|
|
|
|
|
| |
Method | / | Flare | Flare | Flare | Welding | Welding | Welding | |
Liquid pipe diameter | ¢mm | 9.52x2 | 12.7x2 | 12.7x2 | 15.88x1 | 15.88/12.7 | 15.88/12.7 | |
Gas pipe diameter | ¢mm | 15.88x2 | 19.05x2 | 19.05x2 | 28x1 | 28/19.05 | 28/19.05 | |
Power supply | / | 230V/3N/60Hz | ||||||
Outdoor unit | Compressor |
| ||||||
Qty/refrigerant circuit | Nr. | 2/2 | 2/2 | 2/2 | 1/1 | 2/2 | 2/2 | |
Cooling power input* | kW | 7.2 | 9.3 | 11.8 | 12.8 | 15.1 | 17.9 | |
Heating power input** | kW | 7.13 | 9.21 | 11.68 | 12.67 | 14.95 | 17.72 | |
Energy adjustment | % | 50-100 | 50-100 | 50-100 | 0-100 | 40-60-100 | 33-66-100 | |
Axial fans |
| |||||||
Quantity | Nr. | 1 | 1 | 1 | 1 | 2 | 2 | |
Airflow | m3/h | 9400 | 9400 | 12500 | 14200 | 18800 | 18800 | |
Sound pressure level*** | dB(A) | 67 | 67 | 68 | 70 | 71 | 71 | |
Net weight | kg | 170 | 180 | 220 | 280 | 260 | 280 | |
Indoor unit | Centrifugal fans |
|
|
|
|
|
|
|
Quantity | Nr. | 2 | 2 | 2 | 2 | 2 | 2 | |
Airflow | m3/h | 3500 | 4500 | 5650 | 6450 | 7400 | 8550 | |
ESP | Pa | 120 | 100 | 150 | 130 | 180 | 200 | |
Sound pressure level*** | dB(A) | 64 | 64 | 66 | 66 | 68 | 68 | |
Net weight | kg | 90 | 100 | 150 | 160 | 180 | 200 | |
Additional electric heater**** | kW | 2×3 | 2×4 | 2×5 | 2×6 | 2×6 | 2×8 | |
Additional heating coil**** | kW | 22.2 | 28.4 | 35.1 | 40.0 | 46.0 | 53.3 |
Model | Unit | AA52 | AA62 | AA72 | AA88 | AA104 | |
Nominal cooling capacity* | kW | 51.3 | 63.3 | 71.3 | 87.9 | 103.7 | |
Nominal heating capacity** | kW | 58.9 | 72.6 | 81.9 | 100.0 | 115.8 | |
Connection |
|
|
|
|
|
| |
Method | / | Welding | Welding | Welding | Welding | Welding | |
Liquid pipe diameter | ¢mm | 15.88/12.7 | 15.88×2 | 15.88×2 | 15.88×2 | 19.05×2 | |
Gas pipe diameter | ¢mm | 28/19.05 | 28×2 | 28×2 | 28×2 | 35×2 | |
Power supply | / | 230V/3N/60Hz | |||||
Outdoor unit | Compressor |
| |||||
Qty/refrigerant circuit | Nr. | 2/2 | 2/2 | 2/2 | 2/2 | 2/2 | |
Cooling power input* | kW | 18.4 | 23.1 | 26.6 | 28.1 | 39.3 | |
Heating power input** | kW | 18.22 | 22.87 | 26.33 | 27.82 | 38.91 | |
Energy adjustment | % | 30-70-100 | 50-100 | 50-100 | 50-100 | 50-100 | |
Axial fans |
| ||||||
Quantity | Nr. | 2 | 2 | 2 | 2 | 2 | |
Airflow | m3/h | 21500 | 26500 | 29880 | 36500 | 43500 | |
Sound pressure level*** | dB(A) | 71 | 71 | 71 | 71 | 71 | |
Net weight | kg | 330 | 460 | 460 | 780 | 800 | |
Indoor unit | Centrifugal fans |
|
|
|
|
|
|
Quantity | Nr. | 2 | 2 | 2 | 2 | 2 | |
Airflow | m3/h | 9250 | 11450 | 12900 | 14800 | 17100 | |
ESP | Pa | 200 | 300 | 300 | 280 | 500 | |
Sound pressure level*** | dB(A) | 68 | 68 | 69 | 69 | 70 | |
Net weight | kg | 220 | 230 | 300 | 320 | 400 | |
Additional electric heater**** | kW | 2×8 | 2×10 | 2×10 | 2×12 | 2×14 | |
Additional heating coil**** | kW | 57.8 | 71.2 | 80.3 | 98.0 | 113.5 |
**** Optional as request.