Model No.: AW()
Brand: Amrta or OEM
Type: Cooling Only With Electric Heater/Cooling Only/Heat Pump
Cooling Water: Industrial Water
System Type: Closed System
Noise Level: Ultra Low
Certification: CE
Condition: New
Compressor Brand: Copeland / Danfoss / Daikin / Panasonic
Refrigerant: R410A / R407c / R134A / R22
Evaporator: Plate / Tube And Tube
Power Supply: 220V, 380-415V, 50HZ/60HZ
Compressor Qty/Circult: 1/2
Casing(Optional): Heat Recovery
Application Fields: Brewery,Winery,Beverage,Food Process
Packaging: Standard Package for Export Transport
Productivity: 5000SETS/Year
Transportation: Ocean,Air
Place of Origin: China
Supply Ability: 400PCS / Month
HS Code: 8418612090
Port: Qingdao,Shandong,China
Payment Type: L/C,T/T
Incoterm: FOB,CFR,CIF
Good beer requires good process control. The ability to produce the same beer day-in and day-out is important in brewing. A brewery`s most enthusiastic customers expect the same flavor that they have come to know and love, regardless of the batch that their beer comes from. Keeping those customers happy requires the excellent temperature control that can be achieved with a brewery chiller. Amrta Air Conditioning produce brewery chillers specifically for the brewery industry. Amrta can also custom design and fabricate Brewery Water Chiller to meet your brewery needs. We have solutions for the microbrewery to the brewpub from regional to large breweries. We have indoor Glycol Water Chiller and outdoor glycol chillers available. Amrta glycol chillers can also be used in wineries, cider mills and distilleries.
Application areas
● Small Offices, Hotels, Hospitals
● Industry
● Administration
● Small commercial and residential buildings
Why this choice?
● Very high efficiency with R410A
● Very low noise operation
● R410A scroll compressors
● Advanced control
● Unit with pump and optional buffer tank
● Very compact for outdoor or indoor installation
Characteristics
01. Structure. Panels and base frame are made from alvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
02. Compressor. Hermetic scroll type compressor, equipped with the crankcase heater and thermal protection with thermal overload cut-out and crankcase heater mounted on rubber vibration isolators.
03. Axial fan. External rotor type axial fans, equipped with single phase direct drive motors, low noise 6 poles, protection level IP54, provided with a protective outlet grille.
04. Evaporator. High efficiency and low pressure drop stainless steel (AISI 316) water exchangers, with antifreeze heating element (option) and differential pressure switch, factory insulated with flexible close cell material.
05. Condenser. Coils are consisting of seamless copper tubes mechanically expanded into blue hydrophilic aluminum fins,100% fully quality tested; sub cooling circuit to prevent freezing at the base (optional); protected with metal grill.
06. Desuperheater. High efficiency stainless steel brazed plate heat exchanger, factory insulated with flexible close cell material(optional).
07. Refrigerant circuit. Copper tube connection with charge valve, filter, sight glass, gas-liquid separator, thermostatic expansion valve, low pressure switch with automatic reset, high pressure switch with manual reset . The Heat Pump System unit is completed also with 4-way valve, liquid receiver and one way valve.
08. Water circuit. Built with air vent valve, water drain connection, and female-threaded hydraulic connectors Water pump (8kW-30kW), differential pressure switch Expansion tank (8kW-30kW).
09. Electric panel
Compressor contactor
Compressor protection breaker
Fan motor protection breaker
Control circuit protection breaker
Phase sequence relay (only for 3-phase)
Programmable microprocessor controller
10. Optional
Additional electric heater embedded in the coils for defrosting in low temperature ambient. It must be factory installed
Stainless steel covering
Remote condenser
Tube in tube heat exchanger
Water circuit electric heater
Technical Data
Model | Unit | AW20 | AW25 | AW30 | AW35 | AW40 | AW50 |
Cooling * | |||||||
Cooling capacity | kW | 21.5 | 24.8 | 30 | 35.6 | 41 | 50.6 |
Cooling input (without water pump) | kW | 8.2 | 9.03 | 9.39 | 13.2 | 15.02 | 18.8 |
EER | / | 2.62 | 2.75 | 3.19 | 2.7 | 2.73 | 2.69 |
Heating ** | |||||||
Heating capacity | kW | 26.3 | 29 | 34 | 41.8 | 47.2 | 60 |
Heating input (without water pump) | kW | 8.7 | 9.23 | 9.43 | 14.3 | 15.57 | 20.45 |
COP | / | 3.02 | 3.14 | 3.61 | 2.92 | 3.03 | 2.93 |
Hermetic compressor | |||||||
Type | / | ||||||
Quantity/ circuit | / | 2/2 | 2/2 | 2/2 | 2/2 | 2/2 | 2/2 |
Evaporator | |||||||
Type | / | ||||||
Water flow | m3/h | 3.7 | 4.3 | 5.2 | 6.1 | 7.1 | 8.7 |
Water side pressure drop | kPa | 38 | 39 | 42 | 50 | 52 | 52 |
Water connection size | mm | DN40 | DN40 | DN40 | DN40 | DN40 | DN40 |
Circulating pump | |||||||
Power input | kW | 0.75 | 0.75 | 0.92 | --------- | --------- | ----------- |
Axial fans | |||||||
Quantity | Nr. | 1 | 1 | 1 | 2 | 2 | 2 |
Airflow | m3/h | 9000 | 9000 | 12580 | 17000 | 17000 | 22000 |
Overal dimension | |||||||
Length | mm | 1600 | 1600 | 1600 | 2000 | 2000 | 2000 |
Width | mm | 900 | 900 | 900 | 900 | 900 | 900 |
Height | mm | 1080 | 1080 | 1080 | 1080 | 1080 | 1080 |
Noise level *** | dB(A) | 66 | 66 | 68 | 70 | 70 | 70 |
Net weight | kg | 270 | 290 | 310 | 360 | 380 | 465 |
Model AW | 60 | 100 | 130 | 200 | 260 | ||
Cooling capacity* | kW | 65 | 97.5 | 130 | 195 | 260 | |
Cooling power input | kW | 20.8 | 31.4 | 42.1 | 63.6 | 84.2 | |
Heating capacity** | kW | 68 | 102 | 136 | 204 | 272 | |
Heating power input | kW | 20.2 | 30.6 | 41 | 61.2 | 82 | |
Max Input Power | kW | 24 | 35.7 | 47.7 | 71.4 | 95.4 | |
Max Input current | A | 50 | 74 | 97 | 148 | 194 | |
Cooling Running Current | A | 46 | 68 | 89 | 136 | 178 | |
Start-Up Current | A | 167 | 187 | 206 | 374 | 412 | |
Compressor | |||||||
Power supply | / | 380/3/50 | |||||
Brand/Type | / | Daikin/Scroll | |||||
Refrigerant | / | R410a | |||||
Qty/refrigerant circuit | Nr. | 2 | 3 | 4 | 6 | 8 | |
Cooling power input* | kW | 2*9.4 | 3*9.63 | 4*9.77 | 6*9.63 | 8*9.77 | |
Heating power input** | kW | 2*9.1 | 3*9.36 | 4*9.5 | 6*9.36 | 8*9.5 | |
Energy adjustment | % | 0-25-50-75-100 | |||||
Axial fan | |||||||
Quantity | Nr. | 2 | 2 | 2 | 4 | 4 | |
Power input | kW | 2 | 2.5 | 3 | 5 | 6 | |
Airflow | m3/h | 24000 | 36000 | 48000 | 72000 | 96000 | |
Evaporator | |||||||
Type | / | Shell and tube heat exchanger | |||||
Water flow when cooling | m3/h | 11.2 | 16.8 | 22.4 | 33.6 | 44.8 | |
Water flow when heating | m3/h | 11.7 | 17.6 | 23.4 | 35.1 | 46.8 | |
Water side pressure drop *** | kPa | 46 | 52 | 55 | 52 | 55 | |
Water connection size | DN | 50 | 50 | 65 | 2x50 | 2x65 | |
Noise level*** | dB(A) | 70 | 72 | 72 | 74 | 75 | |
Dimensions | |||||||
V type coil | Length | mm | 2000 | 2207 | 2207 | 2207 | 2207 |
Width | mm | 1060 | 1300 | 1300 | 2207 | 2207 | |
Height | mm | 1957 | 2076 | 2076 | 2096 | 2096 | |
Net weight | kg | 620 | 1060 | 1120 | 2160 | 2280 | |
Working weight | kg | 635 | 1090 | 1155 | 2220 | 2350 |
Product Categories : Water Chiller > Brewery Water Chiller